ETL Services
ETL Testing Services
Accredited Laboratory for Testing the Quality and Energy Efficiency of Solid State Lighting
As a member of Intertek’s SATELLITE™ Data Acceptance Program our laboratory is in compliance with ISO 17025 quality management system. Specifically measuring and confirming that commercial lighting products are safe, reliable, eco-friendly and meet all trusted external and internal standards.
ITL has established a documented Quality Management System (QMS) that complies with ISO/IEC 17025 and provides for continuous improvement in order to ensure reliable and accurate test results, in a traceable manner, by utilizing published Standards, proven test methods, industry best practices and on-going quality improvement initiatives.
Our commitment to quality of customer service as well as professional conduct and practices is documented throughout our quality management system (QMS) and are a constant effort and focus.
- CAPABILITIES:
- THERMAL CHAMBER
- Our state-of-the-art thermal chamber provides elevated temperature and humidity testing for performance and reliability of our products.
- The thermal chamber employs a digital control panel for operation.
- Interior volume: >39 cubic-inches
- Temperature range: -60oC to 150oC
- Relative Humidity range: 20% to 98% RH
- IP 5X/6X DUST/SAND CHAMBER
- The IP dust/sand chamber provides time-controlled, non-laminar flow of dust-loaded vertical circulation flow. Accordingly, it is configured simultaneously on product(s) within the product’s enclosure exhaust vacuum pump, and can adjust the exhaust volume and pressure. In addition, the configuration stream controls the temperature in order to ensure that the IEC 60529 (Degrees of protection provided by enclosures (IP Code)) requirements are followed under the intended environmental conditions.
- The IP dust/sand chamber employs a digital control panel for operation.
- Our state-of-the-art IP dust and sand chamber has room to cover over 60 cubic-inches of volume.
- Environmental Conditions:
- Air temperature range: 0oC to 35oC
- Relative Humidity range: 25% to 75% RH
- Atmospheric pressure: 86 to 106 kPa
- Temperature range control: +10oC to +70oC
- ACCREDITATION :
- Intertek, ETL SATELLITE™ Data Acceptance Program
- As a member of Intertek’s SATELLITE™ Data Acceptance Program, itl Illuminations Testing Laboratory operates under the ETL SATELLITE™ Enhanced Level 3 Program as Intertek’s extension-laboratory. We are specifically measuring and confirming that commercial lighting products are safe, reliable, eco-friendly and meet all trusted external and internal standards. As a Level 3 Program facility our staff is approved to conduct hundreds of tests in our Product Safety Lab.
- Under Intertek’s SATELLITE™ Data Acceptance Program, itl has control of our product certification program, enabling speed-to-market with added flexibility of all of our lighting products.
- Here is a top-level list of all standards we have the capability to conduct in-house itl-Product Safety Laboratory:
Standard | Description | Date & Edition |
UL 1598 | UL Standard for Safety for Luminaires | 2008 Ed.3 +R:17Oct2012 |
UL 1598 | UL Standard for Safety for Luminaires | 2018 Ed.4 |
CSA C22.2 No. 250.0-08 | Luminaires | 2008 Ed.3 +R:17Oct2012 |
CSA C22.2 No. 250.0-18 | Luminaires | 2018 Ed.4 |
UL 8750 | Light Emitting Diode (LED) Equipment for Use in Lighting Products | 2015 Ed.2+R:28Apr2020] |
CSA 250.13 | Light emitting diode (LED) equipment for lighting applications | C22.2#250.13:2017 Ed.3 |
UL 2108 | Low Voltage Lighting Systems | 2015 Ed.2+R:06Dec2019 |
CSA C22.2 No. 9.0 | Luminaires | CSA C22.2#9.0:1996 Ed.1+S1 |
UL 153 | Portable Electric Luminaires | 2014 Ed.13+R:24Jul2020 |
CSA C22.2 No. 250.4 | Portable Luminaires | CSA C22.2#250.4:2014 Ed.1 |
UL 1838 | Low-Voltage Landscape Lighting Systems | Ed.3+R:12Apr2017 |
CSA C22.2 No. 250.7-07 | Extra-Low-Voltage Landscape Lighting Systems | R2017 Ed.1 |
UL 924 | Emergency Lighting And Power Equipment | 2016 Ed.10+R:05May2020 |
CSA 141 | Emergency Lighting Equipment | 2015 Ed.5 |
NMX-J-307-ANCE | Luminarios De Uso General Para Interiores Y Exteriores | 2017 |
IEC 60598-1 | Luminaires – Part 1: General requirements and tests | 2014/05/26 Ed: 8 |
IEC 60529 | Degrees of Protection Provided by Enclosures (IP Code) | 2013, Ed: 2.2 |
ASTM B117 | Standard Practice For Operating Salt Spray (Fog) Apparatus | 2019 |
UL 1598A | Supplemental Requirements For Luminaires For Installation On Marine Vessels | 2000 Ed.1+R:28Jan2020 |
|
|
|
Here is a detailed list of approved tests per respective standards (mentioned under #1 above) that we have capability to conduct under the Level 3 ETL Satellite Enhanced Program.
Standard |
ID# |
Test Name |
Clause Number |
UL 1598, 3rd Edition/CSA C22.2 No. |
1 |
Surface ceiling luminaires |
14.2 |
2 |
Surface wall luminaires |
14.3 |
|
3 |
Under-Cabinet Temperature |
14.4 |
|
4 |
Dielectric voltage-withstand |
17.1 |
|
5 |
Bonding circuit impedance |
17.2 |
|
6 |
Elevated Ambient Temperature Luminaires |
12.4 |
|
7 |
Barrier strength |
16.1 |
|
8 |
Mold Stress |
16.4 |
|
9 |
Rain |
16.5.2 |
|
10 |
Sprinkler |
16.5.3 |
|
11 |
Immersion |
16.5.4 |
|
12 |
Conduit knockout and twistout |
16.13 |
|
13 |
Self-threading screw torque |
16.14 |
|
14 |
Loading |
16.15 |
|
15 |
Strain relief |
16.21 |
|
16 |
Ground-screw assembly strength |
16.39 |
|
17 |
Polymeric impact |
16.41 |
|
18 |
Tempered glass impact |
16.22 |
|
19 |
Glass support adhesive |
16.23 |
|
20 |
Glass supported by friction or adhesive |
16.24 |
|
21 |
Type IC inherently protected recessed luminaires (intended for thermal insulation contact) |
14.8 |
|
22 |
Mold stress relief |
16.4 |
|
23 |
Articulate probe |
17.4 |
|
24 |
Cable pull test |
16.40 |
|
25 |
Snap-in or tab-mounted parts pull test without conduit opening |
16.16 |
|
26 |
Snap-in or tab-mounted parts pull test with conduit opening |
16.17 |
|
27 |
Movable joint torsion and pull |
16.20 |
|
28 |
Polymeric support |
16.10 |
|
29 |
Durability of stamped ink marking test |
20.3 |
|
30 |
Recessed Luminaires for use in poured concrete |
14.9 |
|
31 |
Luminaire gasket assembly accelerated aging |
16.5.8 |
Standard |
ID# |
Test Name |
Clause Number |
UL 1598, 4th Edition/CSA C22.2 No. 250.0-2018 |
32 |
Surface ceiling luminaires |
15.2 |
33 |
Surface wall luminaires |
15.3 |
|
34 |
Under-Cabinet Temperature |
15.4 |
|
35 |
Dielectric voltage-withstand |
18.1 |
|
36 |
Bonding circuit impedance |
18.2 |
|
37 |
Elevated Ambient Temperature Luminaires |
13.4 |
|
38 |
Barrier strength |
17.1 |
|
39 |
Mold stress |
17.4 |
|
40 |
Rain |
17.5.2 |
|
41 |
Sprinkler |
17.5.3 |
|
42 |
Immersion |
17.5.4 |
|
43 |
Conduit knockout and twistout |
17.13 |
|
44 |
Self-threading screw torque |
17.14 |
|
45 |
Loading |
17.15 |
|
46 |
Strain relief |
17.21 |
|
47 |
Ground-screw assembly strength |
17.39 |
|
48 |
Polymeric impact |
17.41 |
|
49 |
Tempered glass impact |
17.22 |
|
50 |
Glass support adhesive |
17.23 |
|
51 |
Glass supported by friction or adhesive |
17.24 |
|
52 |
Type IC inherently protected recessed luminaires (intended for thermal insulation contact) |
15.8 |
|
53 |
Mold stress relief |
17.4 |
|
54 |
Articulate probe |
18.4 |
|
55 |
Cable pull test |
17.40 |
|
56 |
Snap-in or tab-mounted parts pull test without conduit opening |
17.16 |
|
57 |
Snap-in or tab-mounted parts pull test with conduit opening |
17.17 |
|
58 |
Movable joint torsion and pull |
17.20 |
|
59 |
Polymeric support |
17.10 |
|
60 |
Durability of stamped ink marking test |
21.3 |
|
61 |
Recessed Luminaires for use in poured concrete |
15.9 |
Standard |
ID# |
Test Name |
Clause Number |
8.7.3.4UL 8750, 2nd Edition |
62 |
Input |
8.2 |
63 |
Temperature test alcove |
8.4 |
|
64 |
Dielectric voltage withstand |
8.6 |
|
65 |
Abnormal – Component Failure |
8.7.2 |
|
66 |
Abnormal – Output Short circuit |
8.7.3.4 |
|
67 |
Abnormal – Output Overload |
8.7.3.5 |
|
68 |
Cord strain and pushback relief |
8.10 |
|
69 |
Adhesive support |
8.13 |
|
70 |
Knockout secureness |
8.17 |
|
71 |
Determination of low-voltage, limited-energy circuit status |
8.16 |
Standard |
ID# |
Test Name |
Clause Number |
CSA C22.2 No. 250.13-2017 |
72 |
Input |
9.2 |
73 |
Temperature |
9.3 |
|
74 |
Dielectric voltage withstand |
9.4 |
|
75 |
Abnormal – Component Failure |
9.5.2 |
|
76 |
Abnormal – Output Short Circuit |
9.5.3.4 |
|
77 |
Abnormal – Output Overload |
9.5.3.5 |
|
78 |
Cord strain and pushback relief |
9.8 |
|
79 |
Adhesive support |
9.11 |
|
80 |
Knockout secureness |
9.14 |
|
81 |
Circuit power limit measurement |
9.6 |
Standard |
ID# |
Test Name |
Clause Number |
UL 2108, 2nd Edition |
82 |
Normal Temperature |
60 |
83 |
Abnormal Recessed Temperature |
61.2 |
|
84 |
Luminaire Drop Impact |
62 |
|
85 |
Strain Relief for Conductor |
63 |
|
86 |
Mounting Means Test |
64 |
|
87 |
Abnormal Operations |
65 |
|
88 |
Luminaire Component Fault |
66 |
Standard |
ID# |
Test Name |
Clause Number |
CSA C22.2 No. 9.0 |
89 |
Surface ceiling luminaires |
11.2 |
90 |
Surface wall luminaires |
11.3 |
|
91 |
Dielectric voltage-withstand |
14.1 |
|
92 |
Bonding circuit impedance |
14.2 |
|
93 |
Elevated Ambient Temperature Luminaires |
9.6.2 |
|
94 |
Conduit knockout and twistout |
13.22 |
|
95 |
Self-threading screw torque |
13.21 |
|
96 |
Loading |
13.3 |
|
97 |
Strain relief |
13.2 |
|
98 |
Polymeric impact |
13.14 |
|
99 |
Tempered glass impact |
13.9 |
|
100 |
Glass supported by friction or adhesive |
13.1 |
|
101 |
Type IC inherently protected recessed luminaires (intended for thermal insulation contact) |
11.9 |
|
102 |
Mold stress relief |
13.18 |
|
103 |
Articulate probe |
14.3 |
|
104 |
Snap-in or tab-mounted parts pull test without conduit opening |
13.11 |
|
105 |
Snap-in or tab-mounted parts pull test with conduit opening |
13.12 |
|
106 |
Movable joint torsion and pull |
13.7 |
|
107 |
Durability of stamped ink marking |
17.3 |
Standard |
ID# |
Test Name |
Clause Number |
UL 153, 13th Edition |
108 |
Normal Temperature |
143-146 |
109 |
Stability |
153 |
|
110 |
Strain Relief |
154 |
|
111 |
Drop |
155 |
|
112 |
Security of Screws |
156 |
|
113 |
Grounding Continuity |
158 |
|
114 |
Dielectric Voltage-Withstand |
159 |
|
115 |
Power-Supply Cord Twist |
157 |
|
116 |
Portable Cabinet Lights – Normal Temperature |
87.1 |
Standard |
ID# |
Test Name |
Clause Number |
CSA C22.2 250.4 |
117 |
Normal Temperature |
14.101 |
118 |
Normal Temperature for Surface-Mounted Cabinet Luminaires |
14.104 |
|
119 |
Normal-Temperature Test for Recess-Mounted Cabinet Lights (Extra Low Voltage) |
14.105 |
|
120 |
Normal Temperature Test for Under-Cabinet Light |
14.106 |
|
121 |
Abnormal Temperature Test for Free Standing Luminaires |
15.1 |
|
122 |
Abnormal Temperature Test for Surface-Mounted Cabinet Luminaires |
15.3 |
|
123 |
Abnormal-Temperature Test for Recess-Mounted Cabinet Lights (Extra Low Voltage System) |
15.4 |
|
124 |
Abnormal Temperature Test for Under Cabinet Lights |
15.5 |
|
125 |
Strain Relief |
16.21 |
|
126 |
Stability |
16.102 |
|
127 |
Drop |
16.108 |
|
128 |
Dielectric voltage-withstand |
17.101 thru 17.103 |
Standard |
ID# |
Test Name |
Clause Number |
UL 1838, 3rd Edition |
129 |
Temperature |
54 |
Standard |
ID# |
Test Name |
Clause Number |
CSA C22.2 No. 250.7 |
130 |
Normal Temperature |
14.101.1 |
131 |
Luminaire assemblies abnormal operation |
15.102 |
|
132 |
Abnormal Severe Condition |
15.102.2 |
|
133 |
Abnormal Vertical Surface |
15.102.3 |
|
134 |
Dielectric voltage-withstand test voltages |
17.101 |
Standard |
ID# |
Test Name |
Clause Number |
UL 924 |
135 |
Leakage Current |
46 |
136 |
Emergency Lighting Control Functionality (ELCF) |
47 |
|
137 |
Input |
49 |
|
138 |
Determination of Low-Voltage, Limited-Energy Circuit Status |
50 |
|
139 |
Temperature |
52 |
|
140 |
Overvoltage Withstand |
53 |
|
141 |
Undervoltage Recharge Capability |
54 |
|
142 |
Voltage Surge |
55 |
|
143 |
Dielectric Voltage-Withstand |
56 |
|
144 |
Strain Relief |
59 |
|
145 |
Conductor Secureness |
60 |
|
146 |
Grounding Continuity |
63 |
|
147 |
Security of Knockout |
64 |
|
148 |
Swivel Torsion and Pull |
65 |
|
149 |
Component Breakdown |
66 |
|
150 |
Humidity Conditioning |
67 |
|
151 |
Mechanical Support Static Load |
69 |
|
152 |
Barrier Strength |
70 |
|
153 |
Rain |
SC4.6 |
|
154 |
Humidity |
SC4.9 |
|
155 |
Minimum Light Output |
SG2 |
Standard |
ID# |
Test Name |
Clause Number |
CSA 141 |
156 |
Operating Conditions (90% of the rating) |
4.3.3.1 |
157 |
Operating Conditions (100% of the rating) |
4.3.3.2 |
|
158 |
Rating (input) |
7.4 |
|
159 |
Temperature |
7.5 |
|
160 |
Leakage Current |
7.6 |
|
161 |
Dielectric Strength |
7.7 |
|
162 |
Charging Means |
7.9 |
|
163 |
Minimum ambient temperature |
7.11 |
|
164 |
Light Output |
7.14 |
Standard |
ID# |
Test Name |
Clause Number |
IEC 60598-1 |
164 |
Dust Proof (IP5X) |
9.2.1 |
165 |
Dust Tight (IP6X) |
9.2.2 |
|
166 |
Jetproof (IPX5) |
9.2.6 |
|
167 |
Powerful Water Jetproof (IPX6) |
9.2.7 |
|
168 |
Watertight (IPX7) |
9.2.8 |
|
169 |
Pressure Watertight (IPX8) |
9.2.9 |
Standard |
ID# |
Test Name |
Clause Number |
NMX-J-307-ANCE |
170 |
Junctions |
7.1.4 |
171 |
Test of resistance to rain |
7.1.5 |
|
172 |
Barriers or partitions |
7.1.6.1 |
|
173 |
Molding strength |
7.1.6.2 |
|
174 |
Test to removable plugs |
7.1.8 |
|
175 |
Load Test |
7.1.12 |
|
176 |
Thermo-tempered glass |
7.1.16 |
|
177 |
Insulation Resistance |
7.2.6 |
Standard |
ID# |
Test Name |
Clause Number |
IEC 60529 |
178 |
Dust Protected (IP5X) |
13.5 |
179 |
Dust Tight (IP6X) |
13.6 |
|
180 |
Water Jets (IPX5) |
14.2.5 |
|
181 |
Power Water Jets (IPX6) |
14.2.6 |
|
182 |
Temporary Immersion (IPX7) |
14.2.7 |
|
183 |
Continuous Immersion (IPX8) |
14.2.8 |
Standard |
ID# |
Test Name |
Clause Number |
UL 1598A |
184 |
Salt Spray (Fog) |
4.1d |